Century is engineered for unmatched durability, long service life, and dependable grounding in the toughest utility environments.
Century delivers high-strength grounding performance for utilities that prioritize durability in the harshest conditions. Designed to resist mechanical damage, deformation, and long-term environmental exposure, Century supports dependable grounding across substations, transmission corridors, and remote infrastructure. With Bare, Camo, and Hide finish options, utilities can match physical visibility and site needs.
| Part Name | Part # | Strands | Fault Current* | Nom. Break Load** | Weight/Length | Overall Diameter | |||
|---|---|---|---|---|---|---|---|---|---|
| kA @ 500 ms | lbf | kgf | lb/kft | kg/km | in | mm | |||
Century 19 No. 4 | Q6C19X4A | 19 | 108.8 | 28,608 | 12,976 | 2,255 | 3,356 | 1.022 | 25.96 |
500 kcmil Copper | CUZ37X1162A | 37 | 101.0 | 15,240 | 6,913 | 1,544 | 2,298 | 0.796 | 20.22 |
| Q6C19X5A | 19 | 87.1 | 22,333 | 10,130 | 1,788 | 2,661 | 0.910 | 23.10 | |
350 kcmil Copper | CUZ37X0973A | 37 | 73.0 | 10,680 | 4,844 | 1,081 | 1,609 | 0.676 | 17.17 |
| Q6C19X6A | 19 | 69.7 | 18,810 | 8,532 | 1,418 | 2,110 | 0.810 | 20.57 | |
| Q6C19X7A | 19 | 55.8 | 14,107 | 6,399 | 1,125 | 1,674 | 0.722 | 18.33 | |
250 kcmil Copper | CUZ37X0822A | 37 | 52.0 | 7,627 | 3,460 | 772 | 1,149 | 0.572 | 14.53 |
| Q6C19X8A | 19 | 44.6 | 11,902 | 5,399 | 892 | 1,327 | 0.643 | 16.32 | |
4/0 Copper | CUZ19X1065A | 19 | 44.0 | 5,983 | 2,714 | 653 | 972 | 0.546 | 13.40 |
| Q6C7X04A | 7 | 40.1 | 10,540 | 4,781 | 827 | 1,231 | 0.613 | 15.57 | |
| Q6C19X9A | 19 | 35.6 | 9,251 | 4,196 | 707 | 1,052 | 0.572 | 14.53 | |
| Q6C7X05A | 7 | 32.1 | 8,228 | 3,732 | 656 | 977 | 0.528 | 13.86 | |
| Q6C19X1055A | 19 | 30.4 | 7,952 | 3,607 | 601 | 895 | 0.510 | 13.40 | |
| Q6C19X10A | 19 | 28.4 | 7,421 | 3,366 | 561 | 835 | 0.910 | 12.94 | |
2/0 Copper | CUZ19X0837A | 19 | 28.0 | 3,763 | 1,707 | 411 | 611 | 0.402 | 10.21 |
| Q6C7X06A | 7 | 25.7 | 6,930 | 3,143 | 520 | 774 | 0.486 | 12.34 | |
1/0 Copper | CUZ19X0745A | 19 | 22.0 | 3,221 | 1,461 | 323 | 481 | 0.368 | 9.36 |
| Q6C7X07A | 7 | 20.6 | 5,198 | 2,358 | 413 | 615 | 0.433 | 11.00 | |
| Q6C19X0860A | 19 | 20.3 | 4,959 | 2,249 | 400 | 595 | 0.430 | 10.92 | |
| Q6C19X0827A | 19 | 19.6 | 4,738 | 2,149 | 365 | 543 | 0.414 | 10.50 | |
| Q6C7X1379A | 7 | 18.8 | 4,568 | 2,072 | 561 | 835 | 0.414 | 10.51 | |
| Q6C7X08A | 7 | 16.4 | 4,385 | 1,989 | 327 | 487 | 0.386 | 9.79 | |
| Q6C19X0750A | 19 | 15.5 | 4,257 | 1,931 | 304 | 452 | 0.375 | 9.53 | |
No. 2 Copper | CUZ7X0974A | 7 | 14.0 | 1,928 | 875 | 205 | 305 | 0.258 | 6.54 |
| Q6C7X09A | 7 | 13.1 | 3,408 | 1,546 | 386 | 574 | 0.343 | 8.72 | |
| Q6C7X10A | 7 | 10.5 | 2,734 | 1,240 | 206 | 306 | 0.306 | 7.76 | |
No. 4 Copper | CUZ2043A | 1 | 9.0 | 1,200 | 544 | 129 | 192 | 0.204 | 5.19 |
| Q6C2576A | 1 | 8.9 | 2,561 | 1,162 | 186 | 277 | 0.258 | 6.54 | |
| Q6C7X0860A | 7 | 7.5 | 2,069 | 938 | 147 | 219 | 0.258 | 6.55 | |
| Q6C2043A | 1 | 5.7 | 1,673 | 759 | 117 | 174 | 0.204 | 5.19 | |
No. 6 Copper | CUZ1620A | 1 | 5.0 | 763 | 346 | 81 | 121 | 0.162 | 4.11 |
| Q6C7X0680A | 7 | 4.7 | 1,295 | 587 | 91 | 135 | 0.204 | 5.18 | |
| Q6C1620A | 1 | 3.7 | 1,100 | 499 | 74 | 110 | 0.162 | 4.11 | |
No. 8 Copper | CUZ1285A | 1 | 3.0 | 499 | 226 | 51 | 76 | 0.129 | 3.28 |
| Q6C1285A | 1 | 2.5 | 696 | 316 | 47 | 69 | 0.129 | 3.28 | |
* Short Circuit Fault Currents are shown in accordance with IEEE80:2013, Table 6, X/R=0, (in kA) ** Breakload Tensile Strength is based upon tested results per ASTM 2.03. | |||||||||

Our original uncoated CCS finish
Bare Copperweld® Copper-Clad Steel (CCS) combines the mechanical strength of steel with the conductivity and corrosion resistance of copper. Continuous copper cladding is metallurgically bonded to a steel core, creating a grounding conductor built for long service life in demanding environments.

Camoflauge your conductor into the surrounding environment
Copperweld Camo™ is a 100% copper finish applied using a proprietary process that alters the surface appearance of the conductor. The result is a grounding conductor that performs like copper while visually blending into steel and galvanized environments, helping reduce theft incentives.

Hide your grounding conductor in plain sight
Copperweld Hide is a PVC-jacketed Copper-Clad Steel grounding conductor designed to visually blend into its surroundings while providing clear, sequential footage markings for installation and maintenance visibility.
Grounding Conductor | Copperweld Copper-Clad Steel (CCS) | |||
Insulation Material | PVC with UL 720 sunlight resistance | |||
Insulation Thickness | 25 mil, +/- 5 mil | |||
Color Options | Black with Parallel Green Stripe Green with Parallel Yellow Stripes Gray Jacket | |||
Polymer Tensile | Min. 1500 psi | |||
Polymer Elongation | Min. 100% | |||
Oxygen Index % | 32, per ASTM D-2863 | |||
Brittleness Temp. | Min. -40° C | |||
Service Life | 30 years, or first high-energy fault | |||
Dielectric* | No dielectric insulation value | |||
Harmonized Marking | Sequential footage markings along the full length of the cable | |||
Packaging | Spools, hand coils, or wooden reels | |||
* Contact Copperweld for dielectric information on specific constructions | ||||
ArcAngel is engineered for easier installation, high fault performance, and proactive maintenance in complex grounding layouts.
ArcAngel is Copperweld’s high-strand-count CCS conductor, engineered to bend easily during installation while combining the electrical performance and corrosion resistance of copper with the strength of steel. With an optional ground fault indicator strand that supports faster inspection and maintenance visibility, ArcAngel helps utilities keep critical grounding systems performing over time. Flexible and durable, ArcAngel helps utilities strengthen critical infrastructure from the ground up.
| Part Name | Part # | Strands | Fault Current* | Nom. Break Load** | Weight/Length | Overall Diameter | |||
|---|---|---|---|---|---|---|---|---|---|
| kA @ 500 ms | lbf | kgf | lb/kft | kg/km | in | mm | |||
ArcAngel 101 | CWAA101 | 61 | 101.0 | 25,089 | 11,380 | 1,905 | 2,835 | 0.941 | 23.89 |
500 kcmil Copper | CUZ37X1162A | 37 | 101.0 | 15,240 | 6,913 | 1,544 | 2,298 | 0.796 | 20.22 |
| CWAA73 | 61 | 73.0 | 17,568 | 7,969 | 1,382 | 2,056 | 0.801 | 20.35 | |
350 kcmil Copper | CUZ37X0973A | 37 | 73.0 | 10,680 | 4,844 | 1,081 | 1,609 | 0.676 | 17.17 |
| CWAA52 | 61 | 52.0 | 13,725 | 6,226 | 987 | 1,468 | 0.677 | 17.19 | |
250 kcmil Copper | CUZ37X0822A | 37 | 52.0 | 7,627 | 3,460 | 772 | 1,149 | 0.572 | 14.53 |
| CWAA44 | 61 | 44.0 | 10,541 | 4,781 | 828 | 1,232 | 0.620 | 15.75 | |
4/0 Copper | CUZ19X1065A | 19 | 44.0 | 5,983 | 2,714 | 653 | 972 | 0.546 | 13.40 |
| CWAA28 | 19 | 28.0 | 7,097 | 3,219 | 524 | 780 | 0.493 | 12.51 | |
2/0 Copper | CUZ19X0837A | 19 | 28.0 | 3,763 | 1,707 | 411 | 611 | 0.402 | 10.21 |
| CWAA22 | 19 | 22.0 | 5,472 | 2,482 | 428 | 637 | 0.445 | 11.30 | |
1/0 Copper | CUZ19X0745A | 19 | 22.0 | 3,221 | 1,461 | 323 | 481 | 0.368 | 9.36 |
| CWAA14 | 19 | 14.0 | 4,019 | 1,823 | 265 | 394 | 0.350 | 8.89 | |
No. 2 Copper | CUZ7X0974A | 7 | 14.0 | 1,928 | 875 | 205 | 305 | 0.258 | 6.54 |
* Short Circuit Fault Currents are shown in accordance with IEEE80:2013, Table 6, X/R=0, (in kA) ** Breakload Tensile Strength is based upon tested results per ASTM 2.03. | |||||||||

Our original uncoated CCS finish
Bare Copperweld Copper-Clad Steel (CCS) combines the mechanical strength of steel with the conductivity and corrosion resistance of copper. Continuous copper cladding is metallurgically bonded to a steel core, creating a grounding conductor built for long service life in demanding environments.

Visual grounding aid to support inspection, maintenance, and field awareness
ArcAngel’s optional indicator strand finish provides a clear visual reference within grounding systems, helping crews quickly identify grounding conductors during installation, inspection, and maintenance activities.